You have a Lelit Bianca, but KPC, KDC, and EC mean nothing to you. This is the page I’d want to look that up on: every setting on the LCC, what it does, and what I use.
LCC stands for Lelit Control Center. It’s the display and control unit in one, and through it you set the temperature of both boilers, the pre-infusion, the shot timer, and more. The Bianca has separate boilers for coffee and steam, and the LCC controls them independently.
The values I use
| Setting | What it is | Mine |
|---|---|---|
| Pre-infusion | Low-pressure time before full pressure | 5 s on light roasts, usually off on dark |
| Off time | Pause after pre-infusion | 4 to 5 s |
| Brew temperature offset | Temperature change during the shot | 0 |
| Coffee temperature | Coffee boiler target | 94 °C on my current beans |
| Steam temperature | Steam boiler target | 125 °C (default) |
| KPC | Coffee boiler, proportional | 0.4 (default) |
| KIC | Coffee boiler, integral | 0.04 (default) |
| KDC | Coffee boiler, derivative | 0.5 |
| BC | Coffee boiler, PID band | 15 °C (default) |
| KPS, KIS, KDS, BS | The same values for the steam boiler | Default |
| EC | Coffee boiler temperature offset | 14 in winter, about 12 in summer |
| TR | Show the real temperature | 1 |
| SAT | How long the shot timer stays visible | 15 s |
The normal settings
These are what you change in daily use. Press the minus button to reach them.
Pre-infusion. Water soaks into the puck at low pressure before full pressure builds. That makes extraction more even and reduces channeling. You set the time in seconds. I mostly use 5 seconds, a good starting point for many light beans. On dark beans I tend not to use it. With pre-infusion you need to grind a little finer.
Off time. How long the machine waits after pre-infusion before the pump starts again. I usually set 4 or 5.
Low Flow Start and Low Flow Final. Only the newest model, the V3, has these. They automate what you can do with the paddle. With Low Flow Start you set how long the machine stays in low flow before switching to full flow, alone or combined with pre-infusion. With Low Flow Final you set when it drops back to low flow at the end, for example to take out some flow and pressure on a roast that otherwise runs too fast. I made a separate video about low flow.
Brew temperature offset. The Bianca raises or lowers the coffee boiler temperature during the extraction. I’ve never used it, and I don’t know how useful it is. It’s a nice idea, and on a Gaggia Classic with Gaggimate it surely works quite well. But the Bianca has so much metal and volume that it’s built for stability, so I’d expect only a minimal change. I leave it at 0.
Coffee temperature. The most important setting. The recommended range is 90 to 98 °C, depending on bean and roast. I do very well with 94 °C on my current beans. Lighter roasts generally benefit from slightly higher temperatures, darker ones from slightly lower.
Steam temperature. The default is 125 °C. You usually don’t need to change it, unless you work with a lot of milk and want to fine-tune the steam pressure.
Steam boiler off. You can disable the steam boiler here, but there’s a shortcut for it below.
Sleep mode. Sets when the Bianca goes into energy saving, which turns off the steam boiler and lets the coffee boiler cool to 70 °C. I find that a good compromise between standby and leaving the machine running all the time.
Units and shot counter. Switch between Celsius and Fahrenheit. In the counter, the top number shows shots since the last reset, the bottom number the total, which you can’t reset.
Two shortcuts
- Hold plus to switch between the current temperature of the coffee boiler and the steam boiler. Handy for seeing the actual temperature instead of the one you set.
- Hold minus for a few seconds and an E for Eco mode appears on the display. The steam boiler is now off and only the coffee boiler heats. I use this when I know I won’t make a cappuccino today.
The service menu
This is where the actual PID settings are. Only change them if you know what you’re doing, because wrong values can destabilize the temperature control.
To get in, hold plus and minus together while you turn the machine on. Make sure you really press both at the same time, because otherwise you reset the settings. For the values, I follow the recommendations from Lelit Insider.
KPC is the proportional value for the coffee boiler during heat-up. It decides how strongly the heating element reacts while the temperature is still rising. A higher value heats more often during heat-up, which builds momentum and can slightly overshoot the target. A lower value means less momentum and a slower rise. The range is 0 to 9.99, the Lelit default is 0.4, and I use 0.4 as well. It’s well balanced for most uses.
KIC gives the heating element regular short pulses in the steady state, once the target is reached, to hold the temperature. A higher value means more frequent activation in standby. The range is also 0 to 9.99. Default and my setting are 0.04. It’s deliberately very low, because a well-insulated boiler doesn’t need much reheating.
KDC is the most interesting one, and it’s where I leave the Lelit default and follow Lelit Insider. It reacts to the rate of temperature change: when the temperature falls, KDC notices and fires the heating element more often, before the temperature drops far below the target. That sounds good, but the derivative term is very sensitive to small fluctuations. A high value can make the element switch on and off nervously even when it isn’t needed. That’s called relay chatter, and it means wear with no real benefit. I reduced mine to 0.5, and the control is calmer and more stable.
BC is the band around the target temperature in which the PID actively regulates. Outside this band, the heating element is simply fully on or fully off. Inside it, the PID does the fine control. The allowed range is 1 to 40, and the default is 15 °C. That’s a good compromise, wide enough for the PID to regulate gently and narrow enough that it isn’t active for longer than it needs to be.
KPS, KIS, KDS, and BS are the same values for the steam boiler. I change nothing here and leave the Lelit defaults.
EC is the temperature offset for the coffee boiler. The temperature sensor doesn’t sit where the water for your espresso leaves the boiler. EC corrects for that difference. With EC at 0, the LCC regulates exactly to the set value. With EC at 10, it regulates 10 °C above what’s displayed, because the sensor measures a different temperature than the water has at the outlet.
I use 14, which is also what Lelit Insider recommends. It depends a bit on your room temperature. My flat was fairly cold when I made the video, so I chose a higher value, and in summer I’d go down to about 12. You can test this yourself with a thermometer. I described how I built my measuring kit in a separate post.
The menu also has the matching offset for the steam boiler.
TR controls the temperature display. At 0 the LCC shows the set temperature rather than the measured one, and you only see the real value while holding plus. At 1 it shows the measured boiler temperature, which can swing around the target. I use 1. It’s less calming to look at but more honest, because you see what’s really happening in the boiler.
TOT refers to the total shot counter.
SAT is the shot timer, which shows the shot time after extraction. The allowed range is 1 to 20 seconds of display time. I changed mine to 15, so I can read the time comfortably but it doesn’t stay up too long.
My take
Most of the defaults are fine. In the service menu I only changed KDC, EC, TR, and SAT.
If you’re choosing between machines rather than tuning one, read my Bianca vs Gaggia comparison.